0,6/1kV CU/XLPE/PVC N2XY CV N2XH XMVK YXV-U CABLE specifications Datasheet
N2XY Cable Application
N2XY Cable Standards:
VDE-0276 Part-603, HD 603.1, IEC 60502, VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1, CE Low Voltage Directive 73/23/EEC and 93/68/EEC
N2XY Cable Construction
Conductor: Conductor conforming to HD383 Class 1 or Class 2
Insulation: XLPE insulation, DIV4 by HD620.1
Core Color: Core color according to DIN VDE 0293, 0276 part 603 or HD186
Number of Cable Cores: one core (single core), two cores (double core), three cores
Core Structure: concentric stranding of cores
Sheath: PVC outer sheath, DMV6 in accordance with HD620.1, generally black
Test voltage: 4 kV
Rated voltage: 0,6/1 kV
Bending radius (min): single-core – 15D;
multicore – 12D
Min. laying temperature: -5°C
Max. short-circuit temperature: 250°C
Operating temperature: -35°C to 90°C
N2XY/YJV Technical data sheet
0.6/1kV-1 core copper conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (ohm/km) | In Air(A) | In Ground(A) |
1X1.5 | 0.7 | 1.4 | 5.5 | 48 | 12.1 | 23 | 32 |
1X2.5 | 0.7 | 1.4 | 5.9 | 59 | 7.41 | 31 | 42 |
1X4 | 0.7 | 1.4 | 6.4 | 75 | 4.61 | 41 | 55 |
1X6 | 0.7 | 1.4 | 6.9 | 95 | 3.08 | 52 | 69 |
1X10 | 0.7 | 1.4 | 8 | 140 | 1.83 | 71 | 92 |
1X16 | 0.7 | 1.4 | 9 | 200 | 1.15 | 92 | 115 |
1X25 | 0.9 | 1.4 | 10.6 | 310 | 0.727 | 120 | 150 |
1X35 | 0.9 | 1.4 | 11.6 | 410 | 0.524 | 150 | 180 |
1X50 | 1 | 1.4 | 13.1 | 510 | 0.387 | 180 | 215 |
1X70 | 1.1 | 1.4 | 15 | 710 | 0.268 | 230 | 265 |
1X95 | 1.1 | 1.5 | 16.8 | 990 | 0.193 | 285 | 320 |
1X120 | 1.2 | 1.5 | 18.4 | 1230 | 0.153 | 335 | 360 |
1X150 | 1.4 | 1.6 | 20.5 | 1450 | 0.124 | 385 | 410 |
1X185 | 1.6 | 1.6 | 22.6 | 1800 | 0.0991 | 450 | 460 |
1X240 | 1.7 | 1.7 | 25.2 | 2300 | 0.0754 | 535 | 535 |
1×300 | 1.8 | 1.8 | 27.8 | 2960 | 0.0601 | 620 | 605 |
1×400 | 2 | 1.9 | 31.4 | 3800 | 0.047 | 720 | 685 |
1×500 | 2.2 | 2 | 34.9 | 4800 | 0.0366 | 835 | 775 |
1X630 | 2.4 | 2.2 | 39.1 | 6100 | 0.0283 | 960 | 865 |
0.6/1kV-2 core copper conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (ohm/km) | In Air(A) | In Ground(A) |
2X1.5 | 0.7 | 1.8 | 10.4 | 105 | 12.1 | 24 | 35 |
2X2.5 | 0.7 | 1.8 | 11.2 | 135 | 7.41 | 33 | 46 |
2X4 | 0.7 | 1.8 | 12.2 | 175 | 4.61 | 43 | 59 |
2X6 | 0.7 | 1.8 | 13.2 | 230 | 3.08 | 55 | 75 |
2X10 | 0.7 | 1.8 | 15.4 | 340 | 1.83 | 76 | 100 |
2X16 | 0.7 | 1.8 | 17.4 | 480 | 1.15 | 97 | 130 |
2X25 | 0.9 | 1.8 | 20.5 | 700 | 0.727 | 130 | 165 |
2X35 | 0.9 | 1.8 | 22.5 | 930 | 0.524 | 160 | 200 |
2X50 | 1 | 1.8 | 20.3 | 1000 | 0.387 | 195 | 240 |
2X70 | 1.1 | 1.8 | 23.3 | 1400 | 0.268 | 245 | 290 |
2X95 | 1.1 | 1.9 | 26.2 | 1950 | 0.193 | 305 | 355 |
2X120 | 1.2 | 2 | 29.4 | 2450 | 0.153 | 355 | 405 |
2X150 | 1.4 | 2.2 | 32.6 | 3000 | 0.124 | 405 | 450 |
2X185 | 1.6 | 2.3 | 36 | 3700 | 0.0991 | 465 | 510 |
0.6/1kV-3 core copper conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (ohm/km) | In Air(A) | In Ground(A) |
3X1.5 | 0.7 | 1.8 | 11.8 | 135 | 12.1 | 21 | 30 |
3X2.5 | 0.7 | 1.8 | 12.7 | 180 | 7.41 | 28 | 39 |
3X4 | 0.7 | 1.8 | 13.8 | 225 | 4.61 | 37 | 51 |
3X6 | 0.7 | 1.8 | 14.9 | 300 | 3.08 | 47 | 64 |
3X10 | 0.7 | 1.8 | 17.2 | 430 | 1.83 | 65 | 86 |
3X16 | 0.7 | 1.8 | 19.4 | 630 | 1.15 | 84 | 110 |
3X25 | 0.9 | 1.8 | 22.8 | 940 | 0.727 | 110 | 140 |
3X35 | 0.9 | 1.8 | 25 | 1250 | 0.524 | 135 | 170 |
3X50 | 1 | 1.8 | 24.4 | 1500 | 0.387 | 170 | 205 |
3X70 | 1.1 | 1.9 | 29.4 | 2140 | 0.268 | 215 | 250 |
3X95 | 1.1 | 2 | 33.6 | 2960 | 0.193 | 265 | 300 |
3X120 | 1.2 | 2.1 | 35.9 | 3760 | 0.153 | 310 | 345 |
3X150 | 1.4 | 2.3 | 39.9 | 4420 | 0.124 | 350 | 385 |
3X185 | 1.6 | 2.4 | 44.1 | 5950 | 0.0991 | 405 | 435 |
3X240 | 1.7 | 2.6 | 51.1 | 7100 | 0.0754 | 480 | 500 |
3X300 | 1.8 | 2.7 | 56.1 | 9000 | 0.0601 | 555 | 565 |
3X400 | 2 | 3 | 62.4 | 10000 | 0.047 | 640 | 640 |
0.6/1kV-4 core copper conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (ohm/km) | In Air(A) | In Ground(A) |
4X1.5 | 0.7 | 1.8 | 12.6 | 160 | 12.1 | 21 | 30 |
4X2.5 | 0.7 | 1.8 | 13.6 | 210 | 7.41 | 28 | 39 |
4X4 | 0.7 | 1.8 | 14.8 | 280 | 4.61 | 37 | 51 |
4X6 | 0.7 | 1.8 | 16 | 380 | 3.08 | 47 | 64 |
4X10 | 0.7 | 1.8 | 18.6 | 530 | 1.83 | 65 | 86 |
4X16 | 0.7 | 1.8 | 21 | 800 | 1.15 | 84 | 110 |
4X25 | 0.9 | 1.8 | 24.9 | 1240 | 0.727 | 110 | 140 |
4X35 | 0.9 | 1.8 | 28.3 | 1600 | 0.524 | 135 | 170 |
4X50 | 1 | 1.8 | 28.4 | 2000 | 0.387 | 170 | 205 |
4X70 | 1.1 | 2 | 33.1 | 2800 | 0.268 | 215 | 250 |
4X95 | 1.1 | 2.1 | 37.1 | 4000 | 0.193 | 265 | 300 |
4X120 | 1.2 | 2.2 | 40.8 | 5000 | 0.153 | 310 | 345 |
4X150 | 1.4 | 2.4 | 45.2 | 6100 | 0.124 | 350 | 385 |
4X185 | 1.6 | 2.6 | 52.1 | 7600 | 0.0991 | 405 | 435 |
4X240 | 1.7 | 2.8 | 57.8 | 9500 | 0.0754 | 480 | 500 |
4X300 | 1.8 | 3 | 63.5 | 12000 | 0.0601 | 555 | 565 |
4X400 | 2 | 3.3 | 70.9 | 16000 | 0.047 | 640 | 640 |
0.6/1kV-5 core copper conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (ohm/km) | In Air(A) | In Ground(A) |
5X1.5 | 0.7 | 1.8 | 11.7 | 170 | 12.1 | 21 | 30 |
5X2.5 | 0.7 | 1.8 | 12.8 | 250 | 7.41 | 28 | 39 |
5X4 | 0.7 | 1.8 | 14 | 330 | 4.61 | 37 | 51 |
5X6 | 0.7 | 1.8 | 15.4 | 460 | 3.08 | 47 | 64 |
5X10 | 0.7 | 1.8 | 18.8 | 700 | 1.83 | 65 | 86 |
5X16 | 0.7 | 1.8 | 21.8 | 1000 | 1.15 | 84 | 110 |
5X25 | 0.9 | 1.8 | 26.2 | 1540 | 0.727 | 110 | 140 |
5X35 | 0.9 | 1.8 | 28 | 2080 | 0.524 | 135 | 170 |
5X50 | 1 | 1.9 | 32.4 | 2760 | 0.387 | 170 | 205 |
5X70 | 1.1 | 2.1 | 37.4 | 3890 | 0.268 | 215 | 250 |
5X95 | 1.1 | 2.2 | 41.7 | 5120 | 0.193 | 265 | 300 |
5X120 | 1.2 | 2.4 | 46.2 | 6530 | 0.153 | 310 | 345 |
5X150 | 1.4 | 2.6 | 53.1 | 8000 | 0.124 | 350 | 385 |
5X185 | 1.6 | 2.8 | 58.9 | 9800 | 0.0991 | 405 | 435 |
5X240 | 1.7 | 3 | 65.6 | 12400 | 0.0754 | 480 | 500 |
5X300 | 1.8 | 3.2 | 72 | 15450 | 0.0601 | 555 | 565 |
0.6/1kV 3+1 core copper conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (ohm/km) | In Air(A) | In Ground(A) |
3X2.5+1X1.5 | 0.7/0.7 | 1.8 | 12.3 | 200 | 7.41/12.1 | 28 | 39 |
3X4+1X2.5 | 0.7/0.7 | 1.8 | 13.4 | 260 | 4.61/7.41 | 37 | 51 |
3X6+1X4 | 0.7/0.7 | 1.8 | 14.6 | 350 | 3.08/4.61 | 47 | 64 |
3X10+1X6 | 0.7/0.7 | 1.8 | 16.9 | 480 | 1.83/3.08 | 65 | 86 |
3X16+1X10 | 0.7/0.7 | 1.8 | 19.4 | 760 | 1.15/1.83 | 84 | 110 |
3X25+1X16 | 0.9/0.7 | 1.8 | 22.8 | 1040 | 0.727/1.15 | 110 | 140 |
3X35+1X16 | 0.9/0.7 | 1.8 | 25.1 | 1420 | 0.524/1.15 | 135 | 170 |
3X50+1X25 | 1.0/0.9 | 1.8 | 28.2 | 1830 | 0.387/0.727 | 170 | 205 |
3X70+1X35 | 1.1/0.9 | 1.9 | 31.9 | 2500 | 0.268/0.524 | 215 | 250 |
3X95+1X50 | 1.1/1.0 | 2.1 | 35.7 | 3400 | 0.193/0.387 | 265 | 300 |
3X120+1X70 | 1.2/1.1 | 2.2 | 39.6 | 4300 | 0.153/0.268 | 310 | 345 |
3X150+1X70 | 1.4/1.1 | 2.3 | 43.6 | 5200 | 0.124/0.268 | 350 | 385 |
3X185+1X95 | 1.6/1.1 | 2.5 | 49.8 | 6500 | 0.0991/0.193 | 405 | 435 |
3X240+1X120 | 1.7/1.2 | 2.7 | 55.3 | 8500 | 0.0754/0.153 | 480 | 500 |
3X300+1X150 | 1.8/1.4 | 2.9 | 57 | 10000 | 0.0601/0.124 | 555 | 565 |
3X400+1X185 | 2.0/1.7 | 3.1 | 70 | 13300 | 0.0470/0.0991 | 640 | 640 |
0.6/1kV 4+1 core copper conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (ohm/km) | In Air(A) | In Ground(A) |
4X2.5+1X1.5 | 0.7/0.7 | 1.8 | 13.2 | 220 | 7.41/12.1 | 28 | 39 |
4X4+1X2.5 | 0.7/0.7 | 1.8 | 14.5 | 320 | 4.61/7.41 | 37 | 51 |
4X6+1X4 | 0.7/0.7 | 1.8 | 15.9 | 420 | 3.08/4.61 | 47 | 64 |
4X10+1X6 | 0.7/0.7 | 1.8 | 18.5 | 650 | 1.83/3.08 | 65 | 86 |
4X16+1X10 | 0.7/0.7 | 1.8 | 21.3 | 950 | 1.15/1.83 | 84 | 110 |
4X25+1X16 | 0.9/0.7 | 1.8 | 25.7 | 1450 | 0.727/1.15 | 110 | 140 |
4X35+1X16 | 0.9/0.7 | 1.8 | 28.2 | 1850 | 0.524/1.15 | 135 | 170 |
4X50+1X25 | 1.0/0.9 | 1.9 | 28.9 | 2500 | 0.387/0.727 | 170 | 205 |
7X70+1X35 | 1.1/0.9 | 2 | 32.2 | 3450 | 0.268/0.524 | 215 | 250 |
4X95+1X50 | 1.1/1.0 | 2.2 | 36.9 | 4700 | 0.193/0.387 | 265 | 300 |
4X120+1X70 | 1.2/1.1 | 2.3 | 40.8 | 6000 | 0.153/0.268 | 310 | 345 |
4X150+1X70 | 1.4/1.1 | 2.5 | 44.7 | 7100 | 0.124/0.268 | 350 | 385 |
4X185+1X95 | 1.6/1.1 | 2.7 | 50.7 | 9000 | 0.0991/0.193 | 405 | 435 |
4X240+1X120 | 1.7/1.2 | 2.9 | 56.4 | 10400 | 0.0754/0.153 | 480 | 500 |
4X300+1X150 | 1.8/1.4 | 3.1 | 64 | 13500 | 0.0601/0.124 | 555 | 565 |
0.6/1kV 3+2 core copper conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (ohm/km) | In Air(A) | In Ground(A) |
3X2.5+2X1.5 | 0.7/0.7 | 1.8 | 13 | 200 | 7.41/12.1 | 28 | 39 |
3X4+2X2.5 | 0.7/0.7 | 1.8 | 14.3 | 260 | 4.61/7.41 | 37 | 51 |
3X6+2X4 | 0.7/0.7 | 1.8 | 15.6 | 350 | 3.08/4.61 | 47 | 64 |
3X10+2X6 | 0.7/0.7 | 1.8 | 17.9 | 480 | 1.83/3.08 | 65 | 86 |
3X16+2X10 | 0.7/0.7 | 1.8 | 20.8 | 760 | 1.15/1.83 | 84 | 110 |
3X25+2X16 | 0.9/0.7 | 1.8 | 25.2 | 1040 | 0.727/1.15 | 110 | 140 |
3X35+2X16 | 0.9/0.7 | 1.8 | 26.8 | 1420 | 0.524/1.15 | 135 | 170 |
3X50+2X25 | 1.0/0.9 | 1.9 | 28.7 | 1830 | 0.387/0.727 | 170 | 205 |
3X70+2X35 | 1.1/0.9 | 2 | 32.2 | 2500 | 0.268/0.524 | 215 | 250 |
3X95+2X50 | 1.1/1.0 | 2.2 | 36.7 | 3400 | 0.193/0.387 | 265 | 300 |
3X120+2X70 | 1.2/1.1 | 2.3 | 40.8 | 4300 | 0.153/0.268 | 310 | 345 |
3X150+2X70 | 1.4/1.1 | 2.4 | 44.5 | 5200 | 0.124/0.268 | 350 | 385 |
3X185+2X95 | 1.6/1.1 | 2.6 | 50.5 | 6500 | 0.0991/0.193 | 405 | 435 |
3X240+2X120 | 1.7/1.2 | 2.8 | 56.1 | 8500 | 0.0754/0.153 | 480 | 500 |
3X300+2X150 | 1.8/1.4 | 3 | 63.7 | 10000 | 0.0601/0.124 | 555 | 565 |
6. Packaging&Delivery.
Packaging Details:Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 7 days(detailly depend on the order quantity)