600/1000V, Cable de servicio triplex de aluminio, 2/0AWG

600/1000V, Cable de servicio triplex de aluminio, 2/0AWG image
Get Latest Price Request a quote
You May Like
Product Details
Product Description
Servicio de cable de aluminio Triplex caída
Palabra clave | El conductor de fase | Neutro desnuda Messenger | Peso por 1.000 pies. (Lb) | Permitido Ampacity+ | |||||||
El tamaño (AWG). | Encalladura | Insul. De espesor. (Mils) | El tamaño (AWG). | El tamaño (kcmil) | Strand- ing | Intensidad nominal (libras). | XLP. | La poli | XLP. | La poli | |
AAAC aleación 6201 NEUTRAL FULL MESSENGER | |||||||||||
Minex | 6 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 101 | 101 | 85 | 70 |
Hippa | 6 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 107 | 107 | 85 | 70 |
Langostinos | 4 | 1 | 45 | 4 | 48.69 | 7 | 1760 | 152 | 152 | 115. | 90 |
Barnacle | 4 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 160 | 160 | 115. | 90 |
El camarón | 2 | 7 | 45 | 2 | 77.47 | 7 | 2800 | 243 | 243 | 150 | 120 |
Gammarus | 1/0 | 7 | 60 | 1/0 | 123.3 | 7 | 4460 | 390 | 390 | 205 | 160 |
Leda | 1/0 | 9 | 60 | 1/0 | 123.3 | 7 | 4460 | 384 | 384 | 205 | 160 |
Dunganese | 2/0 | 7 | 60 | 2/0 | 155.4 | 7 | 5390 | 474 | 474 | 235 | 185 |
Cíclope | 2/0 | 11 | 60 | 2/0 | 155.4 | 7 | 5390 | 474 | 474 | 235 | 185 |
Flustra | 3/0 | 17 | 60 | 3/0 | 195.7 | 7 | 6790 | 587 | 587 | 275 | 215 |
Lepas | 4/0 | 18 | 60 | 4/0 | 246,9 | 7 | 8560 | 728 | 728 | 315 | 245 |
*Palabras clave para el XLP productos aislados están formadas por la adición de «/XLP» a las palabras de código convencional (por ejemplo-Haiotis/XLP).+temperatura de los conductores de 90°C para XLP, de 75°C para el poli; temperatura ambiente de 40°C; emisividad 0,9; 2 ft./seg. viento en el sol.++tamaños designados son: ACSR 6/1 de diámetro equivalente y AAC equivalentes de la resistividad según ASTM B-399 de 6201. |
Palabra clave | El conductor de fase | Neutro desnuda Messenger | Peso por 1.000 pies. (Lb) | Permitido Ampacity+ | |||||||
El tamaño (AWG). | Encalladura | Insul. De espesor. (Mils) | El tamaño (AWG). | El tamaño (kcmil) | Strand- ing | Intensidad nominal (libras). | XLP. | La poli | XLP. | La poli | |
Reducción de la aleación 6201 AAAC MESSANGER NEUTRAL | |||||||||||
La Artemia | 4 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 135 | 135 | 115. | 90 |
El Cangrejo | 4 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 143 | 143 | 115. | 90 |
Solaster | 2 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 216 | 216 | 150 | 120 |
Sandcrab | 1/0 | 7 | 60 | 2 | 77.47 | 7 | 2800 | 347 | 347 | 205 | 160 |
Echinus | 1/0 | 9 | 60 | 2 | 77.47 | 7 | 2800 | 341 | 341 | 205 | 160 |
Cangrejos | 2/0 | 7/w | 60 mls | 2/0 | — | 7 | 2510 | 485.8 | 455.3 | 235 Amp. | 185 Amp. |
Sipho | 2/0 | 7/w | 60 mls | 2/0 | — | 7 | 2510 | 485.8 | 455.3 | 235 Amp. | 185 Amp. |
Fulgar | 3/0 | 17 | 60 | 1/0 | 123.3 | 7 | 4460 | 519 | 519 | 275 | 215 |
Arca | 4/0 | 18 | 60 | 2/0 | 155.4 | 7 | 5390 | 643 | 643 | 315 | 245 |
*Palabras clave para el XLP productos aislados están formadas por la adición de «/XLP» a las palabras de código convencional (por ejemplo-Haiotis/XLP).+temperatura de los conductores de 90°C para XLP, de 75°C para el poli; temperatura ambiente de 40°C; emisividad 0,9; 2 ft./seg. viento en el sol.++tamaños designados son: ACSR 6/1 de diámetro equivalente y AAC equivalentes de la resistividad según ASTM B-399 de 6201. |
Palabra clave | El conductor de fase | Neutro desnuda Messenger | Peso por 1.000 pies. (Lb) | Permitido Ampacity+…………… | ||||||
El tamaño (AWG). | Encalladura | Insul. De espesor. (Mils) | El tamaño (AWG). | Strand- ing | Intensidad nominal (libras). | XLP. | La poli | XLP. | La poli | |
AAC NEUTRAL-Messenger | ||||||||||
Haiotis | 6 | 7/w | 45 mls | 6 | 7 | 563 | 109.1 | 101.6 | 85 amp. | 70 amp. |
Rotula | 6 | 7 | 45 | 6 | 7 | 563 | 103 | 103 | 85 | 70 |
Fusus | 4 | 7/w | 45 mls | 4 | 7 | 881 | 161.8 | 151,7 | 115 Amp. | 90 amp. |
Oyster | 4 | 7 | 45 | 4 | 7 | 881 | 154 | 154 | 115. | 90 |
Clam | 2 | 7 | 45 | 2 | 7 | 1350 | 233 | 233 | 150 | 120 |
Murex | 1/0 | 7 | 60 | 1/0 | 7 | 1990 | 374 | 374 | 205 | 160 |
La púrpura | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 368 | 368 | 205 | 160 |
Nassa | 2/0 | 7 | 60 | 2/0 | 7 | 2510 | 462 | 462 | 235 | 185 |
Melita | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 562 | 562 | 275 | 215 |
Portunus | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 696 | 696 | 315 | 245 |
Nannynose | 336.4 | 19 | 80 | 336.4 | 19 | 6146 | 1118 | 1118 | 420 | 325 |
* Palabras clave para el XLP productos aislados están formadas por la adición de «/XLP» a las palabras de código convencional (por ejemplo-Haiotis/XLP).+ temperatura de los conductores de 90°C para XLP, de 75°C para el poli; temperatura ambiente de 40°C; emisividad 0,9; 2 ft./seg. viento en el sol. |
Palabra clave | El conductor de fase | Neutro desnuda Messenger | Peso por 1.000 pies. (Lb) | Permitido Ampacity+ | ||||||
El tamaño (AWG). | Encalladura | Insul. De espesor. (Mils) | El tamaño (AWG). | Strand- ing | Intensidad nominal (libras). | XLP. | La poli | XLP. | La poli | |
ASCR NEUTRAL-Messenger | ||||||||||
Paludina | 6 | 1 | 45 | 6 | 6/1 | 1190. | 109 | 109 | 85 | 70 |
Voluta | 6 | 7 | 45 | 6 | 6/1 | 1190. | 114 | 114 | 86 | 70 |
Whelk | 4 | 1 | 45 | 4 | 6/1 | 1860 | — | 164 | 115. | 90 |
Periwinkle | 4 | 7 | 45 | 4 | 6/1 | 1860 | 172 | 172 | 115. | 90 |
Caracol | 2 | 7 | 60 | 1/0 | 6/1 | 4380 | 420 | 420 | 205 | 160 |
Neritina | 1/0 | 7 | 60 | 1/0 | 6/1 | 4380 | 420 | 420 | 205 | 160 |
Cenia | 1/0 | 9 | 60 | 1/0 | 6/1 | 4380 | 414 | 414 | 205 | 160 |
Runcina | 2/0 | 7 | 60 | 2/0 | 6/1 | 5310 | 520 | 520 | 235 | 185 |
Tritón | 2/0 | 11 | 60 | 2/0 | 6/1 | 5310 | 512 | 512 | 235 | 185 |
Mursia | 3/0 | 17 | 60 | 3/0 | 6/1 | 6620 | 635. | 635. | 275 | 215 |
Zuzara | 4/0 | 18 | 60 | 4/0 | 6/1 | 8350 | 789 | 789 | 315 | 245 |
Limpet | 336.4 | 19 | 80 | 336.4 | 18/1 | 8680 | En el 1167 | En el 1167 | 420 | 325 |
*Palabras clave para el XLP productos aislados están formadas por la adición de «/XLP» a las palabras de código convencional (por ejemplo-Haiotis/XLP).+temperatura de los conductores de 90°C para XLP, de 75°C para el poli; temperatura ambiente de 40°C; emisividad 0,9; 2 ft./seg. viento en el sol. |
Palabra clave | El conductor de fase | Neutro desnuda Messenger | Peso por 1.000 pies. (Lb) | Permitido Ampacity+ | ||||||
El tamaño (AWG). | Encalladura | Insul. De espesor. (Mils) | El tamaño (AWG). | Strand- ing | Intensidad nominal (libras). | XLP. | La poli | XLP. | La poli | |
ASCR REDUCIDO NEUTRAL-Messenger | ||||||||||
Vieira | 4 | 1 | 45 | 6 | 6/1 | 1190. | — | 142 | 115. | 90 |
Strombus | 4 | 7 | 45 | 6 | 6/1 | 1190. | 151 | 151 | 115. | 90 |
Berberechos | 2 | 7 | 45 | 4 | 6/1 | 1190. | 220 | 220 | 150 | 120 |
Janthina | 1/0 | 7 | 60 | 2 | 6/1 | 2853 | 366 | 366 | 205 | 160 |
Ranella | 1/0 | 9 | 60 | 2 | 6/1 | 2853 | 360 | 360 | 205 | 160 |
Cavolinia | 2/0 | 7 | 60 | 1 | 6/1 | 3550 | 453 | 453 | 235 | 185 |
Clio | 2/0 | 11 | 60 | 1 | 6/1 | 3550 | 444 | 444 | 235 | 185 |
Sanddollar | 3/0 | 19/w | 60 mls | 1/0 | 6/1 | 4380 | 565 | 552 | 275 Amp. | 215 Amp. |
Aega | 3/0 | 17 | 60 | 1/0 | 6/1 | 4380 | 549 | 549 | 275 | 215 |
Sepia | 4/0 | 19/w | 60 mls | 2/0 | 6/1 | 5310 | 699 | 684 | 315 Amp. | 245 Amp. |
Cerapus | 4/0 | 18 | 60 | 2/0 | 6/1 | 5310 | 681. | 681. | 315 | 245 |
Cowery | 336.4 | 19 | 80 mls | 336/4 | 18/1 | 8680 | 1209 | En el 1167 | 420 Amp. | 325 Amp. |
*Palabras clave para el XLP productos aislados están formadas por la adición de «/XLP» a las palabras de código convencional (por ejemplo-Haiotis/XLP).+temperatura de los conductores de 90°C para XLP, de 75°C para el poli; temperatura ambiente de 40°C; emisividad 0,9; 2 ft./seg. viento en el sol. |
Hay mucho debate continúan como si el cobre es mejor para usos eléctricos o de aluminio. Si el precio no era un factor crítico, la mayoría sugeriría ir para la plata como se dice ser el mejor conductor de electricidad, pero tiene una resistencia baja. Sin embargo, cuando se trata de cableado eléctrico, el precio es un factor, como es la eficiencia.
Aplicaciones:
Para el suministro de energía de la utilidad de las líneas a la weatherhead del consumidor. Para el servicio a 600 voltios o menos (fase a fase) a una temperatura de los conductores de 75°C como máximo para el aislamiento de polietileno o de 90°C como máximo para crosslinked aislamiento.
Construcción:
Strand concéntricos o comprimido 1350-H19 al conductor, de polietileno o de aislamiento de polietileno crosslinked, concéntricos strand AAC, ACSR o aleación 6201 mensajero neutral.
Estándares:
B-230 Cable de aluminio 1350-H19 para usos eléctricos
B-231 Los conductores de aluminio, Concentric-Lay filamentos
B-232 Los conductores de aluminio, Concentric-Lay filamentos, reforzado de acero recubierto (ACSR)
B-399 Concentric-Lay filamentos 6201-T81 Conductores de aleación de aluminio
B-498 Zinc-Coated el núcleo de acero cables para los conductores de aluminio, acero reforzado (ACSR).
Servicio de triple cable caída cumple o supera todos los requisitos aplicables de ANSI/ICEA S-76-474 del cuerpo.
Hay mucho debate continúan como si el cobre es mejor para usos eléctricos o de aluminio. Si el precio no era un factor crítico, la mayoría sugeriría ir para la plata como se dice ser el mejor conductor de electricidad, pero tiene una resistencia baja. Sin embargo, cuando se trata de cableado eléctrico, el precio es un factor, como es la eficiencia.
Nuestra empresa
Yifang grupo eléctrico especializado principalmente en el cable&cables, incluyendo designment,producción y venta.
Los productos son principalmente cubriendo bajas,medium,alta tensión(1KV A 220 KV XLPE) cable de alimentación aislado,aislados con PVC, cable de alimentación, cable de ABC, la creación de cable de mando de cable, cable de goma del cable de soldadura Etc.
Nuestros cables XLPE pueden ser fabricados según especificaciones de la empresa que es equivalente a la IEC 60502, IEC60332,IEC60754. Algunos índices son superiores a por encima de estándar internacional.
Nuestro certificado
Preguntas frecuentes
1.Q: ¿una fábrica o empresa comercial?
R: base industrial de Henan, China, con más de 500 trabajadores.
2.Q: ¿Cómo puedo visitar?
R: Seguro,si es necesario, realizaremos el controlador para recogerlo.
3.Q: ¿Cómo puedo obtener algunas muestras?
R: Póngase en contacto conmigo a continuación, muestra Determin y la dirección de envío.
4.Q: ¿Alguna vez has suministrado cables a nuestro país?
R: Cables Yifang se han vendido a más de 100 países y regiones del mundo. puede ponerse en contacto conmigo para más detalles.
5.Q: ¿Cuál es su MOQ?
R: Normalmente MOQ a 500 metros de cables de diámetro grande.Póngase en contacto conmigo para obtener información detallada si tienes cable específico de requisito.
6. Q: ¿Cuándo puedo obtener el precio?
R: suele citar dentro de 6 horas después de que recibimos su consulta.
7.Q: ¿Cuál es su hora de entrega?
R: Según la cantidad del pedido.Normalmente nuestro plazo de entrega es de 3 a 20 días hábiles.
Nosotros somos China 600/1000V, Cable de servicio triplex de aluminio, 2/0AWG fabricante y proveedor,Puede obtener más detalles con el correo electrónico, obtendrá un precio económico o un precio de fábrica.
Get Latest Price Request a quote
Popular 2/0AWG Productos
PAC, Cable Aéreo Paralelo, 2/0AWG
AAAC 2AWG, 4AWG, 2/0AWG, 4/0AWG Conductor Desnudo Aéreo Astmb399
Servicio de caída triplex, cable ABC, 2/0AWG, cable aéreo de racimo Cyclops Lt Ab 1100V
Cable Aéreo de Alta Tensión 15-35kv ACSR 1/0AWG, 2/0AWG, 3/0 AWG, 4/0 AWG, 336.4 Mcm Cable de Árbol
Popular cable de aluminio Productos
Núcleo de aluminio con chaqueta XLPE 10kv Par trenzado aéreo ABC cable aéreo agrupado
Cable de Conductor de Aluminio Aéreo ABC según la Norma AS/NZS
Cable de servicio de caída dúplex con conductor de aluminio y aislamiento de XLPE
Norma IEC 2 Núcleos de Bajo Voltaje XLPE PE Aislados 2X150mm2 Cable de Aluminio ABC
Tres Núcleos 3X16mm2 Conductor de Aluminio Cable ABC Cable Aéreo Cable de Potencia
Proveedor de cable aéreo agrupado con aislamiento XLPE para cableado aéreo
Popular Cable de servicio triplex de aluminio Productos
Popular Triplex caída de servicio de cable Productos
Cable de aluminio triplex de servicio de caída aérea
Cable de Línea Aérea Retorcido 0.6/1kv Hilo de Servicio Triplex
Tags: 2/0AWG, cable de aluminio, Cable de servicio triplex de aluminio, Triplex caída de servicio de cable